The Ningdian® Gas Filled Thermometers from China factory can be installed in most existing piping and tank applications ,which are available as direct reading ,or remote reading with stainless steel bulbs and armored capillary .The sensing bulb should be placed in a none-turbulent area of piping or ducting and as close the center of the flow as possible.
In tanks,it should be placed in an area of the tank that will provide a good average of the temperature of the fluid contained .The bulb should be protected from corrosive or abrasive media and excessively high pressure .The usual method of protection is the use of a thermowell.
Case: |
304 Stainless steel case with snap-in ‘u’ring gasketed clear lexan molded window. The case can be filled with Silicon Oil to protect from shaking and so on. |
Bulb: |
Stainless steel |
Pointer: |
Adjustable ,balanced aluminum with matte black or red polish. |
Temperature Range : |
-40~60℃, -20~60℃, 0~120℃, 0~150℃, 0~200℃, 0~300℃, 0~400℃, 0~500℃,50~300℃/-40~160℉,0~100℉, 0~220℉, 20~240℉, 25~125℉, 50~400℉, 50~500℉, 50~600℉, 50~750℉ |
Accuracy: |
±1.5% |
Screw: |
1/2”NPT,3/4”NPT or 1/2”BSP, 3/4”BSP |